Skip to content

BT turns all thermostats in a group up to 30C if one thermostat are out of battery #1608

Open
@carlhye

Description

@carlhye

Description

In a group of multiple thermostats and an external sensor, if one thermostat runs out of battery, BT turn all thermostats up to 30C

This has now been experienced in two different groups. One group with 5 thermostats, and in a group with 8 thermostats.

In one example 'C2_COM_Galleriet1_1' is out of battery, and for some reason this causes it to go to 30C.
When BT is enabled the BT climate entity is then also set to 30C, which in turn turn all other thermostats in the group to target 30C

Entities in the group (with the BT entity disabled)
Image

History of the BT climate entity - you can se when the battery ran out.
Image

Steps to Reproduce

  1. Define a group with multiple themostats and one external sensor (I don't know if external sensor is needed to reproduce)
  2. Wait for a thermostat to run of of battery

Expected behavior:

All thermostats with enough battery, continues to work and keep a normal temperature, only the thermostat with low battery could maybe have a weird behaviour.

Actual behavior:

All thermostats in the group incl. the BT climate entity is set to 30C and when you try to turn it down, it resets to 30C after a short period of time.

Versions and HW

Home Assistant: 2025.2.4 and 2025.2.5
Zigbee2MQTT: 2.1.1-1
Better Thermostat: 1.6.1

TRV(s): Aqara SRTS-A01 + 1 external sensor pr group: Aqara WSDCGQ12LM Temp & humidity sensor

Debug data

diagnostic data

{
  <html><head><title>500 Internal Server Error</title></head><body>
<h1>500 Internal Server Error</h1>
Server got itself in trouble
<script defer src="https://static.cloudflareinsights.com/beacon.min.js/vcd15cbe7772f49c399c6a5babf22c1241717689176015" integrity="sha512-ZpsOmlRQV6y907TI0dKBHq9Md29nnaEIPlkf84rnaERnq6zvWvPUqr2ft8M1aS28oN72PdrCzSjY4U6VaAw1EQ==" data-cf-beacon='{"rayId":"919048705ea798eb","version":"2025.1.0","r":1,"token":"487d177cfcac4d5c9675f22604ef6048","serverTiming":{"name":{"cfExtPri":true,"cfL4":true,"cfSpeedBrain":true,"cfCacheStatus":true}}}' crossorigin="anonymous"></script>
</body></html>
}

debug log

Log from the Z2M integration running the involved thermostat. The issues has been observed on two different installations of Z2M on the same HA installation (running 4 in total)

Log file attached:

9336c2b0_zigbee2mqtt_2025-02-28T12-04-12.065Z.log

graphs