The effects of long-term contact lens wear on corneal thickness, curvature, and surface regularity
- PMID: 10647727
- DOI: 10.1016/s0161-6420(99)00027-5
The effects of long-term contact lens wear on corneal thickness, curvature, and surface regularity
Abstract
Purpose: To evaluate the effect of long-term contact lens wear on corneal thickness, curvature, and surface regularity.
Design: A prospective, clinic-based, case-control study.
Participants: A total of 40 eyes of 20 normal subjects and 64 eyes of 35 subjects wearing contact lenses for more than 5 years were evaluated.
Methods: The Orbscan Corneal Topography System was used to evaluate the entire corneal thickness and curvature, anterior curvature and the anterior and posterior elevation topographic patterns in normal eyes and subjects wearing contact lenses on a regular basis for more than 5 years. Indices of TMS-1 Corneal Topography System were used to determine corneal surface regularity in subjects wearing contact lenses and normal eyes. All topographic examinations were performed after contact lenses had been removed for at least 2 weeks.
Main outcome measures: The entire corneal thickness, curvature, surface regularity index (SRI), surface asymmetry index (SAI), potential visual acuity (PVA) and topographic patterns were compared between normal eyes and subjects wearing contact lenses for more than 5 years.
Results: The 64 eyes of 35 subjects evaluated by the Orbscan instrument had an average of 13.45 +/- 6.42 years of contact lens wear. The mean corneal thickness in the center and in eight peripheral areas measured in contact lens wearing subjects was significantly reduced by about 30 to 50 microm compared to normal subjects (P < 0.001 for central and peripheral sites). No correlation was noted between central corneal thickness and degree of myopia in diopters (r = 0.15, 0.10 < P < 0.25). The corneal curvature, maximum keratometry (Max K) and minimum keratometry (Min K) readings, were significantly steeper in eyes wearing contact lenses than normal eyes (P < 0.01 for Max K and Min K measured by both instruments). No difference in the mean corneal astigmatism was noted between groups. The SRI and SAI, but not the PVA index, of the TMS-1 were significantly greater in contact lens wearers than in the control group (P < 0.01 for both SRI and SAI, P = 0.15 for PVA). The color-coded patterns of all curvature and elevation maps made with both instruments showed no significant difference between subjects wearing contact lenses and the control group. There was no significant difference between corneal curvature measurements taken with the Orbscan System or the TMS-1 System in both normal and contact lens groups.
Conclusions: Long-term contact lens wear appears to decrease the entire corneal thickness and increase the corneal curvature and surface irregularity.
Similar articles
-
Corneal thickness indices discriminate between keratoconus and contact lens-induced corneal thinning.Ophthalmology. 2002 Dec;109(12):2336-41. doi: 10.1016/s0161-6420(02)01276-9. Ophthalmology. 2002. PMID: 12466180
-
Corneal surface regularity and the effect of artificial tears in aqueous tear deficiency.Ophthalmology. 1999 May;106(5):939-43. doi: 10.1016/S0161-6420(99)00513-8. Ophthalmology. 1999. PMID: 10328393 Clinical Trial.
-
Assessing the severity of keratitis sicca with videokeratoscopic indices.Ophthalmology. 2003 Jun;110(6):1102-9. doi: 10.1016/s0161-6420(03)00245-8. Ophthalmology. 2003. PMID: 12799233
-
Contact lenses and corneal deformation: cause, correlate or co-incidence?Acta Ophthalmol (Copenh). 1990 Dec;68(6):661-8. doi: 10.1111/j.1755-3768.1990.tb01690.x. Acta Ophthalmol (Copenh). 1990. PMID: 2080694 Review.
-
The current state of corneal reshaping.Eye Contact Lens. 2005 Sep;31(5):209-14. doi: 10.1097/01.icl.0000179709.76832.4f. Eye Contact Lens. 2005. PMID: 16163012 Review.
Cited by
-
Robust automatic segmentation of corneal layer boundaries in SDOCT images using graph theory and dynamic programming.Biomed Opt Express. 2011 Jun 1;2(6):1524-38. doi: 10.1364/BOE.2.001524. Epub 2011 May 12. Biomed Opt Express. 2011. PMID: 21698016 Free PMC article.
-
The time course of the onset and recovery of axial length changes in response to imposed defocus.Sci Rep. 2020 May 20;10(1):8322. doi: 10.1038/s41598-020-65151-5. Sci Rep. 2020. PMID: 32433541 Free PMC article.
-
Acute hypoxia influences collagen and matrix metalloproteinase expression by human keratoconus cells in vitro.PLoS One. 2017 Apr 20;12(4):e0176017. doi: 10.1371/journal.pone.0176017. eCollection 2017. PLoS One. 2017. PMID: 28426715 Free PMC article.
-
[Acute alteration of corneal topography].Ophthalmologe. 2014;111(7):672-5. doi: 10.1007/s00347-013-2998-4. Ophthalmologe. 2014. PMID: 24549684 German. No abstract available.
-
Corneal aberration changes after rigid gas permeable contact lens wear in keratokonic patients.J Curr Ophthalmol. 2016 Aug 30;28(4):194-198. doi: 10.1016/j.joco.2016.08.002. eCollection 2016 Dec. J Curr Ophthalmol. 2016. PMID: 27830203 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous