@F1p F1p released this 29 May 12:35
· 3 commits to master since this release

** Firmware for official ebay-sold hardware: **

Change Log

  • Additional Entities added for Computed Input & Output Power, split into components DHW/Heating/Cooling to use in Integral Helpers
  • Faster refresh rate of for Flow Rate, Pumps & 3-way Valves entities
  • Fixed a bug when adjusting the Room Thermostat Setpoint when operating in a Fixed Flow Cooling mode
  • Modified the logic for Eco DHW Boost to start operating when requested during a non-prohibited state
  • ESP Clock is now Synced with FTC Clock and Telnet Debugging logs now contain a timestamp
  • Modified the Estimated Input Power for 8kW Split units
  • Modified JSON "LastSvc" and "LastSvcReply" to only display the user Requested Service Commands

⚠️There is a known and intermittent issue for Generation 1 (ESP8266) users where the configuration page of the webpage menu can appear partially blank - this is due to memory limitations and only occurs on v6.1.x and above. Refreshing the page restores the parameter options.